Instant Object Studio



Error messages in SDL Trados Studio: 'Object reference not set to an instance of an object' and 'TM Update failed'

  1. Instant Object Studio Tutorial
  2. Fsx Instant Object Studio
  • Every object has an instance Id. I'm on a bus so I can't double check on my computer but i think you can pass either instance or id in each object to deliver what you'll need. So you can check like obj. Instance sorry just game jammed or I'd probably be more awake and able to remember which one game maker uses.
  • Instant Object Studio Flight1 has released a new tool, Instant Object Studio. This evening I had a play with the demo version and I must say I am surprised by the tool.
  • But there is a function in Instant Object Studio to help you with that already. In the material settings you can select that the texture should be stretched along the X and Y axes. With the Area button you can then choose the area of the texture you want.
  • Object reference not set to an instance of an object. Try to restart Visual Studio and see if it helps. Will Wu responded on 11 Dec 2019 3:41 AM.

Instant Object Studio Tutorial

Instant Object Studio Flight1 has released a new tool, Instant Object Studio. This evening I had a play with the demo version and I must say I am surprised by the tool.

000001649|3/27/2017 10:10 AMInstant Object StudioInstantStudio
SDL Trados Studio

Symptom 1

You open a document in the Editor view and you move to any segment in the document. SDL Trados Studio displays the following error message:

Object reference not set to an instance of an object

When you try to confirm a segment, you receive the error message:

TM update failed

Symptom 2

You start Studio immediately after installing it. When you switch between different dialogs and views, Studio displays the following error message:

Object reference not set to an instance of an object

Solution 1

If Studio starts, but shows the error message Object reference not set to an instance of an object when you switch between different dialogs and views:

  1. Open Studio.
  2. Activate the view where the error occurs (for example the Editor view).
  3. Click View > Reset Window Layout.
  4. Click OK to confirm resetting the window layout.

If the error message still appears after following the steps above, follow the instructions under Solution 2 below.

Solution 2

  1. Rename the setting files and run a repair installation

    1. Close all SDL applications.
    2. Go to the following folder:
      • SDL Trados Studio 2011
        • Windows XP: C:Documents and Settings[USER_NAME]Application DataSDLSDL Trados Studio10.0.0.0
        • Windows Vista/7/8: C:Users[USER_NAME]AppDataRoamingSDLSDL Trados Studio10.0.0.0
      • SDL Trados Studio 2014
        • Windows XP: C:Documents and Settings[USER_NAME]Application DataSDLSDL Trados Studio11.0.0.0
        • Windows Vista/7/8: C:Users[USER_NAME]AppDataRoamingSDLSDL Trados Studio11.0.0.0
      • SDL Trados Studio 2015
        • Windows XP: C:Documents and Settings[USER_NAME]Application DataSDLSDL Trados Studio12.0.0.0
        • Windows Vista/7/8: C:Users[USER_NAME]AppDataRoamingSDLSDL Trados Studio12.0.0.0
    3. Rename the following XML files (for example, add an underscore before/after the filename):
      • BaseSettings.xml
      • Plugincache.xml
      • UserSettings.xml

    NOTE: If you do not find this folder, make sure that these files are not hidden. See article #000001137: Show hidden files and folders on Windows operating systems.

  2. Run a repair installation

    1. Open the Control Panel:
      • Windows Vista/7: Start > Control Panel > Programs > Programs and Features.
      • Windows 8: Right-click on the screen at bottom-left corner and choose Control Panel > Uninstall a Program.
    2. Click to highlight the damaged SDL Trados Studio version and click Repair.
    3. Restart Studio.

Fsx Instant Object Studio

Instant object studio p3d
There are a few possible explanations for this problem:
You installed Studio using Download and run...(also known as Save and run) or Run... in your Internet browser. This means that you have run the installer from within your browser without first saving the installer locally on your computer.
Studio was running while installing a Cumulative Update or a Service Pack.
Various Studio layout settings could not be properly accepted and updated while starting Studio.